Commercial Water Treatment System Rentals

A Rental Fleet for Your Commercial Water Treatment Needs

At WaterTectonics, our rental fleet of commercial water treatment systems offers semi-modular and fully mobile water treatment systems with plug-and-play functionality, ensuring your project is up and running quickly. Whether you’re setting up a short-term pilot project or need multiple custom systems for a long-term project, we have you covered. Our water treatment solutions come with flexible rental terms, lease-to-own agreements, or buyback options.  

what is electrocoagulation?

Why Choose WaterTectonics for Your Commercial Water Treatment Rental Needs?

  • Engineered Design: We offer pre-deployment review and professional engineering evaluation of your process solution 
  • Competitive Rental Rates: Affordable options for all project sizes
  • Turnkey Field Services: Comprehensive setup, teardown, and operational support
  • Compliance Monitoring & Reporting: System options include inline realtime water quality monitoring, allowing our systems to automatically recirculate water for re-treatment in the event of a system upset rather than discharge out of spec water. Optional Eagle Eye remote monitoring and data visualization tools are at your fingertips
  • Continual Upgrades: We reinvest in our assets to provide the latest technology and the best performance

Complete Water Solutions for Every Rental Need

Emergency Rental
If you have an emergency and need a water treatment system now, contact us immediately. We can be reached by phone at 866-402-2298 or via email at contactme@watertectonics.com.

Upcoming Projects
Planning a project and need a short-term or long-term rental solution? Learn more about our packaged systems options and full-service installation & training offerings including: installation, commissioning, training, maintenance, and construction services. We offer rental water treatment for any project duration.

Pilot Testing
Interested in piloting a new water treatment technology? Explore our in-house lab treatability services providing a way to de-risk your investment in a water treatment project before installing a system at full-scale and our wide range of engineering services and deliverables. Rent reverse osmosis water systems or other water filtration system rentals to pilot new technologies.

Comprehensive Rental Process

Project Planning
* Discharge permitting
* Equipment design and layout
* Water management plans
* Regulatory submittals

Mobilization
* Logistics coordination
* Freight to site
* Equipment interconnect
* Commissioning and performance verification

Operations
* Operational training/certification 
* On-site field service support
* Discharge sample collection
* Water quality reporting and management 

Demobilization
* Coordination of tear down activities
* Equipment break down and pack out
* Outbound freight and project close out

Commissioning

Explore Our Commercial Water Treatment Rental Treatment Systems

Electrocoagulation
Electrocoagulation (EC) is a broad-spectrum treatment technology that removes total suspended solids (TSS) and turbidity, metals, oils, bacteria and other contaminants from water.

How does electrocoagulation work?
As water passes through the electrocoagulation cell, multiple reactions take place simultaneously. First, a metal ion is driven into the water, the first step in coagulation. On the surface of the cathode, water is hydrolyzed into hydrogen gas and hydroxyl groups. Meanwhile, electrons flow freely to destabilize surface charges on suspended solids and emulsified oils. As the reaction continues, large flocs form that entrain suspended solids, heavy metals, emulsified oils and other contaminants. Finally, the flocs are removed from the water in downstream solids separation and filtration process steps.

What contaminants are targeted with electrocoagulation?
Contaminants targeted are: TSS/turbidity, metals, oils, bacteria, silica, and TBT. Learn more about EC here. If target contaminants require filtration with granular activated carbon (PFAS, PCBs, VOCs, etc.), ion exchange or other specialty media, pre-treatment with electrocoagulation is a critical step when water has high TSS/turbidity loading, removing solids prior to granular activated carbon treatment for PFAS for example, prevents fouling and preserves the life in the granular activated carbon medias.

Chemical Treatment
Chemical treatment includes a broad range of treatment options that involve injecting chemicals into water under controlled conditions to generate a desired set of reactions. These systems include delivery of liquid, dry, and concentrated (via makedown systems) chemicals.

How does chemical treatment work?
Water is collected in a source tank or pond and pumped through the system by a treatment pump. Influent water quality can be analyzed for real-time parameters to influence dose rates. Chemicals may be stored inside or outside of a treatment enclosure. As water is pumped, chemicals are injected into the water using automated and adjustable dosing pumps. Various mixing techniques may be integrated into the system as well in the form of pipe flocculators, mechanical mixers, and other devices.

What contaminants are targeted with chemical treatment?
Contaminants targeted are: TSS/turbidity, metals, oils, and silica. Learn more about chemical treatment here.

pH Adjustment 
pH adjustment systems involve the addition of acids or bases in order to adjust pH to a desirable range for reuse or discharge.

How does pH adjustment work?
Treatment for pH requires neutralizing the solution in the preferred direction by either adding an acid or base to the water. Depending on the level of pH adjustment needed, weak acids and bases or strong acids and bases can be used. Multiple factors need to be considered in system design, including the buffering nature of the water, need for single or multi-directional adjustment, and designing for gross & trim control points. Once appropriate chemistries are selected and process controls are designed, we build systems in a variety of configurations to meet the design requirements.

What contaminants are targeted with pH adjustment?
Contaminants targeted are: pH. Learn more about pH adjustment here. 

Dissolved Air Flotation
Dissolved Air Flotation (DAF) is a treatment process that utilizes micro-bubbles to lift and separate contaminants in a reaction tank. A cone bottom design and surface scraper system automate sludge removal of the separated material.

How does dissolved air flotation work?
Water enters the flocculation chamber where it can optionally be dosed with a polymer to help enhance floc formation. It then travels through serpentine piping to allow for additional reaction time. Micro-bubbles are injected into the water prior to entering the separation chamber through micro-bubble injection quills. Micro-bubbles help lift flocs to the surface of the separation chamber. A layer of sludge forms on the surface of the separation chamber, and an automated skimmer periodically scrapes the sludge into a sludge tank. Treated water exits the separation chamber near the middle to ensure that floating and settled floc carryover is minimized. A clear well tank serves as the primary holding tank prior to any downstream filtration. Finally, sludge that is removed by the automated scraper and sludge that settles to hoppers at the base of the system can be removed by use of an automated sludge pump.

What contaminants are targeted with dissolved air flotation?
Contaminants targeted are: oils. Learn more about dissolved air flotation (DAF) here.

Media Filtration 
Media filtration involves pumping water through a pressurized bed of water treatment media. Systems can utilize different medias depending on the treatment need and are also configurable with automated backwashing functionality. Media filters are a common type of water filtration equipment for rent.

How does media filtration work?
Water is pumped under pressure through a bed of filtration media. As material builds up on the top of the media bed, it creates a pressure differential between the top and bottom of the filter. Filters with automated backwashing features monitor this pressure differential in real-time and can automatically trigger backwash cycles when pressures exceed design criteria. The backwash process uses feed water to reverse flow on each media vessel, one pod at a time, until all of the pods have been cleaned. At the end of the backwash cycle, the pressure differential is restored to baseline, and the filter returns to normal use.

What contaminants are targeted with media filtration?
Contaminants targeted are: TSS/turbidity. Learn more about media filtration here.

Ultrafiltration
Ultrafiltration (UF) is a membrane filtration process that utilizes pressure to separate particulate matter from soluble components in water.

How does ultrafiltration work? 
The ultrafiltration membranes act as semi-permeable barriers that allow particles to be captured or pass through, based on the pore size. Suspended solids and dissolved substances of high molecular weight in feed water are retained by the membrane, while water and low molecular weight substances pass through the membrane as product water. Self-cleaning and periodic chemical rinses keep membranes functioning at transmembrane pressure (TMP) design levels.

What contaminants are targeted with ultrafiltration?
Contaminants targeted are: TSS/turbidity. Learn more about ultrafiltration (UF) here. 

Granular Activated Carbon
Granular Activated Carbon (GAC) is an adsorptive media that excels at reducing a wide range of contaminants from water.

How does granular activated carbon work?
Prior to treatment with GAC, suspended solids must be removed from the water so that the GAC bed is not turned into a filtration bed. Once water meets pre-treatment specifications, it is pumped under pressure through a bed of granular activated carbon media. Contaminants adsorb on to the GAC media and are captured in the bed. Bed life can be modeled in the lab or monitored at full-scale. Oftentimes, a lead-lag configuration is utilized to prevent breakthrough of target contaminants. Once contaminants are detected in between the lead and lag vessels, the bed positions can be swapped or media can be replaced per client preference.

What contaminants are targeted with granular activated carbon?
Contaminants targeted are: metals, TPH, PFAS, COD, PCBs, BTEX, TOC, PCP, PAHs/cPAHs, and VOCs/cVOCs. Learn more about granular activated carbon (GAC) here. 

Ion Exchange
Ion exchange (IX) is a process that takes advantage of surface reaction kinetics whereby undesirable contaminants are removed from water by binding to a resin product that releases a desirable compound in its place.

How does ion exchange work?
Ion exchange resins include a wide range of customizable resins, with the most common being cation and anion exchange resins. Some of these resins are regenerable and others are single-use. Vessels can be configured in lead-lag configurations to prevent breakthrough of target contaminants. Bed life can be modeled using software for many applications. We help our clients design and build ion exchange systems in a wide range of temporary, mobile, and permanent applications.

What contaminants are targeted with ion exchange?
Contaminants targeted are: metals, PFAS, nitrates, fluoride, and mercury. Learn more about ion exchange (IX) here. 

Reverse Osmosis
Reverse osmosis is a membrane filtration process that utilizes pressure to reduce dissolved solids in water. You can rent reverse osmosis water systems for short-term or long-term projects.

How does reverse osmosis work?
Reverse osmosis is a mechanical process in which pressure is applied to a concentrate solution to overcome the osmotic pressure and reverse the direction of the solute flow. Membranes are designed with cross-flow filtration technology. Pressurized solute flows across the surface of a membrane through the feed channel spacer. Approximately 10-15% of the feed water will diffuse through the membrane and flow through the permeate spacer around to the permeate tube. Rejected brine that does not enter the product channel is combined with reject brine from other membranes and can either be treated by a reject-recovery reverse osmosis system or disposed of via other methods. Depending on water source, EC pre-treatment may enhance recovery.

What contaminants are targeted with reverse osmosis?
Contaminants targeted are: metals, PFAS, TDS and sulfate. Learn more about reverse osmosis (RO) here. 

Have water treatment rental questions?

Have additional questions about our complete water treatment solution rentals? Visit our Rental Solutions Page for additional information. To discuss your site-specific rental needs, contact us today!

We offer a wide range of water treatment rental equipment, including:
Reverse osmosis systems
Electrocoagulation rental systems
Chemical treatment rental systems
Installation services
Environmental remediation solutions
Dissolved air flotation rental systems
Granular activated carbon rental systems
Ion exchange rentals
Industrial water treatment rentals
Construction dewatering equipment
Construction stormwater treatment systems
Groundwater treatment systems
Suspended solids filtration
Temporary water treatment solutions
Short-term and long-term equipment rentals
Upgrades for existing water treatment systems
Turnkey water treatment systems
Rental sand filter systems
pH adjustment rental systems

Please complete the form below to download our fact sheet.